• Coatings, paints & inks

Bayhydrol® U XP 2766

Anionic, hydroxyfunctional polyester-polyurethan dispersion.Binder for the formulation of water-reducible 2K-PUR coatings.

Contact an Expert
i
Market Switch
Selection will influence the results you get.
Copied to clipboard

About

Product Types

  • Dispersion
  • PU dispersion
  • Waterbased dispersion
  • PU dispersion - hydroxy-functional

Material

Coatings, paints & inks
Hard, Solvent-free, Waterborne, Easy mixing, Flexible, High functional, Low viscous, Elastic

General Characterization

No data available

Storage Conditions

No data available

Sampling

No data available

Packaging Type

No data available

Technical Properties & Datasheets

Product description

Anionic, hydroxyfunctional polyester-polyurethan dispersion.Binder for the formulation of water-reducible 2K-PUR coatings.

Applications

Bayhydrol® U XP 2766 is a hydroxyfunctional polyester-polyurethan dispersion which can be thinned with water to application viscosity. In combination with hydrophobic polyisocyanates (e.g. Desmodur® N 3600, N 3900 , XP 2730) and/or with hydrophilic polyisocyanates (e.g. Bayhydur 3100, 304, 305, XP 2487/1, XP 2655) high performance, hard-elastic two-component polurethane-hydrocoatings can be formulated.Two-component polyurethane hydrocoatings based on Bayhydrol® U XP 2766 are characterized by good appearance ( high gloss , low haze value).Bayhydrol® U XP 2766 is compatible with various polyacrylic dispersions (e.g. Bayhydrol® A 145, A 2470, A 2601, A XP 2645 , A 2695, A XP 2770). On account of the many potential co-reactants, compatibility testing should always be carried out.

Form supplied

approx. 37 % in water / DMEA (approx. 61.3 : 1.7)

Specification

Property Test Condition Value Unit Standard
Viscosity at 23 °C, (D = 40 s^(-1) 100 - 1,000 mPa*s DIN EN ISO 3219/A.3
Non-volatile content (1 g / 1 h / 125 °C) approx. 35 - 39 % DIN EN ISO 3251
pH 7,0 - 8,0 DIN ISO 976

Typical Values

Property Test Condition Value Unit Standard
Acid number approx. 11 mg KOH/g DIN EN ISO 2114
Density at 20 °C approx. 1,06 g/ml DIN EN ISO 2811
OH content (solid resin) approx. 4,0 %

Storage

- Storage in original sealed Covestro container. - Recommended storage temperature: > 0 - 30 °C. - Protect from frost, heat and foreign material. General information: The product is sensitive to frost. Prolonged freezing can damage the product irreversibly. Prolonged storage at higher temperatures may result in a decrease of viscosity and/or an increase of average particle size, possibly resulting in sedimentation or coagulation. The viscosity of the product is largely governed by the pH. As the pH may decrease during storage, a decrease in viscosity is also to be expected. The viscosity can be restored to its original value by the addition of small amounts of an aqueous 10 % solution of dimethyl ethanol amine. Contamination with certain bacteria, fungi or algae may render the product unusable.

Storage time

Covestro represents that, for a period of three months following the day of shipment as stated in the respective transport documents, the product will meet the specifications or values set forth in section "specifications or characteristic data" above, what ever is applicable, provided that the product is stored in full compliance with the storage conditions set forth in and referenced under section "storage" above and is otherwise handled appropriately.The lapse of the three months period does not necessarily mean that the product no longer meets specifications or the set values. However, prior to using said product, Covestro recommends to test such a product if it still meets the specifications or the set values. Covestro does not make any representation regarding the product after the lapse of the three months period and Covestro shall not be responsible or liable in any way for the product failing to meet specifications or the set values after the lapse of the three months period.

Processing

After use, formulation and application equipment should be cleaned immediately or left to soak in water. Warm water, alkaline cleaning agents or alkaline isopropyl alcohol are suitable for cleaning.

Health and Safety Information

Before working with this product, you must read and become familiar with the available information regarding its risks, proper use, and safe handling. This information is provided in various formats, including the current Safety Data Sheet (SDS) and product label. SDS can be accessed via the following link:

Safety Data Sheets (SDS) for Covestro products | Covestro

For further questions, please use the contact information provided on this technical data sheet.

Disclaimer

Responsibility and Liability

The use of Covestro products, technical assistance, and information (regardless of how provided) is outside Covestro’s control and is solely the responsibility of the customer. The customer must conduct adequate testing to determine the suitability of products for its intended use, including but not limited to technical, health, safety, and environmental aspects. Unless otherwise agreed in writing, all products are sold exclusively under Covestro’s standard conditions of sale, which prevail in case of conflict and are available upon request.
The terms and conditions of sale and delivery are available via the following link:

https://order.covestro.com/covestrostorefront/saleConditions

All information is provided “as is” without warranties, express or implied, including merchantability or fitness for a particular purpose, and is subject to change without notice. To the maximum extent permitted by law, Covestro disclaims, and the customer assumes all liability for losses, damages, or claims arising out of use of Covestro products, technical assistance, or information. Any statement or recommendation not expressly contained in Covestro documentation is unauthorized and shall not bind Covestro. Nothing herein shall be construed as encouraging or recommending the use of any product in conflict with any claim of any patent. No license is implied or in fact granted under the claims of any patent.

Restrictions on Regulated Applications

This product is not intended for use in regulated applications such as agriculture, cosmetics, drinking water contact, medical products (e.g., medical devices), toys, or similar uses subject to specific regulatory requirements. Prior written approval from Covestro is required before this product may be used in any regulated application. The customer is solely responsible for ensuring compliance with all applicable laws and determining product suitability. Covestro disclaims all liability and warranties for unauthorized regulated uses.

Conditional Use in Regulated Applications

This product may be suitable for use in food contact. However, use in such applications requires prior written approval from Covestro. Legal requirements for such applications vary by country and jurisdiction, and the customer is solely responsible for verifying compliance with all applicable laws and regulations. Without Covestro’s written approval, the product may not be distributed or used for regulated purposes, and Covestro disclaims all liability for such use.

Trial or development Product

This product is provided on a trial basis only. Hazard and performance information may be incomplete and may be updated as additional data becomes available. No assurances are given regarding conformity, processability, or long-term performance. Use of this product is at the sole responsibility and risk of the customer. All warranties, express or implied, are disclaimed. Continued supply is not guaranteed and may be discontinued without notice. Covestro accepts no liability for damages or losses arising from the use of this trial product.

Typical Value

The values provided are typical only and do not represent binding specifications. Unless expressly confirmed in a written contract, these values are not part of the contractual quality agreement and must not be relied upon as a warranty or guarantee of product performance.

Sample

Samples provided by Covestro are intended solely for evaluation and testing purposes by the customer and may not be used in commercial applications, resold, transferred to third parties (except qualified testing service providers acting on behalf of the customer), reverse engineered, modified, or used in any manner not explicitly authorized in writing by Covestro. Samples are provided ‘as-is’ without any warranties, express or implied, including fitness for a particular purpose. Customers are solely responsible for ensuring safe handling, regulatory compliance, and suitability of the material for their intended evaluations. Covestro disclaims all liability for damages or losses arising from the use of samples.

Contact Information

Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .

Downloads

Technical Data Sheet
Download
Safety Data Sheet
No direct download available, please visit www.productsafetyfirst.covestro.com

Do you want to know more about Bayhydrol® U XP 2766?
Get in touch with our experts!

contact us

What is the topic you are contacting us about today?

How would you describe yourself?

What type of material are you interested in?

What type of industry are you interested in?

What type of inquiry is this?

How can we contact you?

What is the subject of your request?

Your Message to us:

* Mandatory Fields

Information on data processing can be found in our privacy statement.

Request a sample
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"en","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"No results for","MaxItem":5}

Request a sample

Request a quote
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"en","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"No results for","MaxItem":5}

Request a quote

Compare