• Films

Bayfol® HX200

Bayfol® HX200 is a light-sensitive, self-developing photopolymer film which can be used to produce phase holograms in the form of volume reflection and volume transmission holograms. Bayfol® HX200 can be recorded with appropriate laser light within the visible spectral wavelength range from 440 nm to 680 nm. For hologram formation no further post-treatment is necessary, e.g. neither wet nor thermal treatment. Bayfol® HX200 consists of a three layer stack of a substrate, a light-sensitive photopolymer and a protective cover film. The substrate is a cellulose triacetate film (TAC), and the protective cover is a polyethylene film (PE). The protective cover film can be removed from the photopolymer.The product is capable of being used for a variety of types of volume holograms. Layer Stack, Schematic

Contact an Expert
i
Market Switch
Selection will influence the results you get.
Copied to clipboard

About

Product Types

  • Polycarbonate film

Material

Films
Low retardation, Thermoformable, Coated, Light management

General Characterization

No data available

Storage Conditions

No data available

Sampling

No data available

Packaging Type

No data available

Technical Properties & Datasheets

Product description

Bayfol® HX200 is a light-sensitive, self-developing photopolymer film. It comprises a three-layer stack: A cellulose triacetate film (TAC) substrate, a light-sensitive photopolymer layer, and a polyethylene film (PE) protective cover. The PE cover can be removed from the photopolymer layer.

 

Applications

Bayfol® HX200 is used for producing phase holograms, specifically volume reflection holograms and volume transmission holograms. The product is applicable to various types of volume holograms. Its self-developing property and the ability to record across a range of visible light wavelengths make it suitable for different holographic applications in both research and industrial settings.

Layer Stack Schematic:

Typical Values

General Properties

Property Test Condition Value Unit Standard
Typical substrate thickness 60 microns acc. to ISO 4593, 23°C
Typical photopolymer thickness 16 microns white light interferometer
Typical cover layer thickness 40 microns acc. to ISO 4593, 23°C

Optical Properties

Property Test Condition Value Unit Standard
Light transmittance Unrecorded film, w/o cover foil, see spectrum in appendix % ASTM E 01348
Haze after UV flood cure 2) < 2 % ASTM D 1003
Index of refraction nD of the substrate 1,485 Prism coupler
Index of refraction nD of the photopolymer unrecorded 1,500 Prism coupler
Index of refraction nD of the photopolymer after UV flood cure 2) 1,505 Prism coupler

Holographic Performance Data: Denisyuk Holograms

Property Test Condition Value Unit Standard
Spectral diffraction efficiency η > 95 % ISO 17901-1, by transmittance of zero-order transmitted wave
Spectral bandwidth (full width at half maximum) > 15 nm ISO 17901-1, by transmittance of zero-order transmitted wave
Recording dosage (needed to achieve above mentioned values) approx. 30 mJ/cm² Recording wavelenght: λ = 532 nm; Power density: PR= 4.6 mW/cm²

Holographic Performance Data: Reflection Holograms in 2-Beam Geometry

Property Test Condition Value Unit Standard
Maximum refractive index modulation ∆n1 at λ = 633 nm Applied total dosage approx. 15 mJ/cm² > 0,03 ISO 17901-2
Maximum refractive index modulation ∆n1 at λ = 532 nm Applied total dosage approx. 20 mJ/cm² > 0,03 ISO 17901-2
Maximum refractive index modulation ∆n1 at λ = 457 nm Applied total dosage approx. 25 mJ/cm² > 0,03 ISO 17901-2

Shrinkage and Spectral Shift

Property Test Condition Value Unit Standard
Effective thickness shrinkage after recording and UV flood cure 2) approx. 1,4 % Reflection holograms
Spectral shift in Denisyuk Holograms after recording and UV flood cure 2) approx. -8 nm Wavelength deviation between recording / reconstruction
XXXXX SOME OBSOLETE ENTRYS XXXXX SOME OBSOLETE ENTRYS XXXXX SOME OBSOLETE ENTRYS
λ = 633 nm > 0,03
λ = 532 nm > 0,03
λ = 457 nm > 0,03
λ = 633 nm Applied total dosage approx. 15 mJ/cm²
λ = 532 nm Applied total dosage approx. 20 mJ/cm²
λ = 457 nm Applied total dosage approx. 25 mJ/cm²
Typical recording dosage needed to achieve above ∆n1 values
Maximum refractive index modulation ∆n1 per recording wavelengt λ ISO 17901-2
Optical Properties

Property Test Condition Value Unit Standard
Light transmittance Unrecorded film, w/o cover foil, see spectrum in appendix % ASTM E 01348
Haze after UV flood cure 2) < 2 % ASTM D 1003
Index of refraction nD of the substrate 1,485 Prism coupler
Index of refraction nD of the photopolymer unrecorded 1,500 Prism coupler
Index of refraction nD of the photopolymer after UV flood cure 2) 1,505 Prism coupler
Holographic Performance Data: Denisyuk Holograms

Property Test Condition Value Unit Standard
Spectral diffraction efficiency η > 95 % ISO 17901-1, by transmittance of zero-order transmitted wave
Spectral bandwidth (full width at half maximum) > 15 nm ISO 17901-1, by transmittance of zero-order transmitted wave
Recording dosage (needed to achieve above mentioned values) approx. 30 mJ/cm² Recording wavelenght: λ = 532 nm; Power density: PR= 4.6 mW/cm²

Holographic Performance Data: Reflection Holograms in 2-Beam Geometry

  • s-polarized beams, external angles of incidence -22° (object beam), +42° (reference beam) in air 

  • typical power density: 9 - 23 mW/cm²

 

 

 

 

Property Test Condition Value Unit Standard
Maximum refractive index modulation ∆n1 at λ = 633 nm Applied total dosage approx. 15 mJ/cm² > 0,03   ISO 17901-2
         
Maximum refractive index modulation ∆n1 at λ = 532 nm Applied total dosage approx. 20 mJ/cm² > 0,03   ISO 17901-2
         
Maximum refractive index modulation ∆n1 at λ = 457 nm Applied total dosage approx. 25 mJ/cm² > 0,03   ISO 17901-2
Shrinkage and Spectral Shift

 

 

 

 

Property Test Condition Value Unit Standard
Effective thickness shrinkage after recording and UV flood cure 2) approx. 1,4 % Reflection holograms
Spectral shift in Denisyuk Holograms after recording and UV flood cure 2) approx. -8 nm Wavelength deviation between recording / reconstruction

Storage

The unrecorded photopolymer film should be stored in the original and sealed Covestro container that is used for delivery, whenever possible.The storage temperature shall be kept at ≥15°C and ≤ 25 °C.While the recorded film is quite stable, the unrecorded photopolymer film should be protected from light, humidity, heat and foreign materials.

Storage time

Six months Storage Time is recommended.

Processing

General information about handling instructions under dark room conditions 

The product is light sensitive. Exposure to light prior to the holographic exposure might sacrifice the refractive index modulation Δn1 and diffraction efficiency η. Examples for tolerable expositions in dark room environment (dim yellow light) without sacrificing holographic performance are given in table below. Test condition: Photopolymer film laminated on glass and illuminated with illuminant positioned at a distance of 30 cm above.

Illuminant

Maximum exposure intensity

Maximum exposure time

OSRAM PARATHOM DECO CLASSIC A Yellow 1 Watt LED E27

2,6 µW/cm²

5 min

PHILIPS AccentColor Miniglobe Yellow 1 Watt LED E27

0,8 µW/cm²

30 min

Direct Transmission Spectrum

Transmissions spectrum (recorded in a darkened laboratory with spectrometer according to ASTM E 0134) of the unrecorded photopolymer film after removal of the protective cover film.

Gerneral informaition on flood cure and bleaching

These are recommendations and should serve as guidelines. According to the specific equipment components and the type of product to be produced, deviations from these guidelines might be necessary. The bleaching can also be adapted to the required product performance. Example: Conditions for mercury lamps High temperatures (above 60°C at the film) should be avoided because they can lead to deformation of the substrate. Dichroic mirrors that reflect UV-light and transmit IR-radiation and a fused silica panel in front of the lamp can reduce the amount of IR-radiation and thus further reduce the temperature.The following conditions were found to be favorable:

  • Photopolymer layer on substrate laminated to glass
  • Dosage: 5,000-10,000 mJ/cm²• Intensity at the sample: 40 mW/cm

These data were found using a mercury lamp (MH-Strahler UV-400 H) of Hönle UV Technology (http://www.hoenle.de).

Health and Safety Information

Before working with this product, you must read and become familiar with the available information regarding its risks, proper use, and safe handling. This information is provided in various formats, including the current Safety Data Sheet (SDS) and product label. SDS can be accessed via the following link:

Safety Data Sheets (SDS) for Covestro products | Covestro

For further questions, please use the contact information provided on this technical data sheet.

Disclaimer

Responsibility and Liability

The use of Covestro products, technical assistance, and information (regardless of how provided) is outside Covestro’s control and is solely the responsibility of the customer. The customer must conduct adequate testing to determine the suitability of products for its intended use, including but not limited to technical, health, safety, and environmental aspects. Unless otherwise agreed in writing, all products are sold exclusively under Covestro’s standard conditions of sale, which prevail in case of conflict and are available upon request.
The terms and conditions of sale and delivery are available via the following link:

https://order.covestro.com/covestrostorefront/saleConditions

All information is provided “as is” without warranties, express or implied, including merchantability or fitness for a particular purpose, and is subject to change without notice. To the maximum extent permitted by law, Covestro disclaims, and the customer assumes all liability for losses, damages, or claims arising out of use of Covestro products, technical assistance, or information. Any statement or recommendation not expressly contained in Covestro documentation is unauthorized and shall not bind Covestro. Nothing herein shall be construed as encouraging or recommending the use of any product in conflict with any claim of any patent. No license is implied or in fact granted under the claims of any patent.

Restrictions on Regulated Applications

This product is not intended for use in regulated applications such as agriculture, cosmetics, drinking water contact, food contact, medical products (e.g., medical devices), toys, or similar uses subject to specific regulatory requirements. Prior written approval from Covestro is required before this product may be used in any regulated application. The customer is solely responsible for ensuring compliance with all applicable laws and determining product suitability. Covestro disclaims all liability and warranties for unauthorized regulated uses.

Typical Value

These values are provided as typical data only and do not constitute binding specifications or warranted performance, unless explicitly agreed by Covestro in writing. Performance may vary depending on factors including, but not limited to, mold/die, processing conditions and coloring/pigmentation. Unless otherwise stated, values are based on standardized test specimens at room temperature.

Sample

Samples provided by Covestro are intended solely for evaluation and testing purposes by the customer and may not be used in commercial applications, resold, transferred to third parties (except qualified testing service providers acting on behalf of the customer), reverse engineered, modified, or used in any manner not explicitly authorized in writing by Covestro. Samples are provided ‘as-is’ without any warranties, express or implied, including fitness for a particular purpose. Customers are solely responsible for ensuring safe handling, regulatory compliance, and suitability of the material for their intended evaluations. Covestro disclaims all liability for damages or losses arising from the use of samples.

Contact Information

Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .

Downloads

Technical Data Sheet
Safety Data Sheet
No direct download available, please visit www.productsafetyfirst.covestro.com

Do you want to know more about Bayfol® HX200?
Get in touch with our experts!

contact us

Qual é o assunto sobre o qual nos está a contactar hoje?

Como se descreveria?

Em que tipo de material está interessado?

Em que tipo de indústria está interessado?

Que tipo de pedido de informação é este?

Como o podemos contactar?

Qual é o assunto do seu pedido

A sua mensagem para nós

*Campos obrigatórios

As informações sobre o tratamento de dados podem ser consultadas na nossa Declaração de Privacidade.

Request a sample
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"pt","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"No results for","MaxItem":5}

Request a quote
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"pt","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"No results for","MaxItem":5}

Compare