Before working with this product, you must read and become familiar with the available information regarding its risks, proper use, and safe handling. This information is provided in various formats, including the current Safety Data Sheet (SDS) and product label. SDS can be accessed via the following link:
Safety Data Sheets (SDS) for Covestro products | Covestro
For further questions, please use the contact information provided on this technical data sheet.
Product description
822-06-0
Specification
| Property | Test Condition | Value | Unit | Standard |
|---|---|---|---|---|
| NCO content | (calculated from GC) | ≥ 49.7 | % | internal method |
| Assay (GC) | ≥ 99.5 | % | internal method | |
| Color value (Hazen) | ≤ 30 | DIN EN 1557 | ||
| Hydrolyzable chlorides | ≤ 100 | mg/kg | internal method |
Typical Values
| Property | Test Condition | Value | Unit | Standard |
|---|---|---|---|---|
| Viscosity at 25 °C | approx. 3 | mPa*s | DIN EN ISO 3219/A.3 | |
| Density at 20 °C | approx. 1.05 | g/ml | DIN EN ISO 2811 | |
| Total chlorides | ≤ 800 | mg/kg | ||
| Flash point | approx. 135 | °C | DIN EN 22 719 | |
| Vapor pressure at 25 °C | approx. 1.4 · 10^-2 | hPa |
Storage
- Storage in original sealed Covestro container. - Recommended storage temperature: 0 - 30 °C. - Protect from moisture, heat and foreign material. General information: The product is sensitive to moisture. Storage at higher temperatures will result in increase of color and viscosity.
Storage time
Covestro represents that, for a period of nine months following the day of shipment as stated in the respective transport documents, the product will meet the specifications or values set forth in section "specifications or characteristic data" above, what ever is applicable, provided that the product is stored in full compliance with the storage conditions set forth in and referenced under section "storage" above and is otherwise handled appropriately.The lapse of the nine months period does not necessarily mean that the product no longer meets specifications or the set values. However, prior to using said product, Covestro recommends to test such a product if it still meets the specifications or the set values. Covestro does not make any representation regarding the product after the lapse of the nine months period and Covestro shall not be responsible or liable in any way for the product failing to meet specifications or the set values after the lapse of the nine months period.
Health and Safety Information
Disclaimer
Responsibility and Liability
The use of Covestro products, technical assistance, and information (regardless of how provided) is outside Covestro’s control and is solely the responsibility of the customer. The customer must conduct adequate testing to determine the suitability of products for its intended use, including but not limited to technical, health, safety, and environmental aspects. Unless otherwise agreed in writing, all products are sold exclusively under Covestro’s standard conditions of sale, which prevail in case of conflict and are available upon request.
The terms and conditions of sale and delivery are available via the following link:
https://order.covestro.com/covestrostorefront/saleConditions
All information is provided “as is” without warranties, express or implied, including merchantability or fitness for a particular purpose, and is subject to change without notice. To the maximum extent permitted by law, Covestro disclaims, and the customer assumes all liability for losses, damages, or claims arising out of use of Covestro products, technical assistance, or information. Any statement or recommendation not expressly contained in Covestro documentation is unauthorized and shall not bind Covestro. Nothing herein shall be construed as encouraging or recommending the use of any product in conflict with any claim of any patent. No license is implied or in fact granted under the claims of any patent.
Restrictions on Regulated Applications
This product is not intended for use in regulated applications such as agriculture, cosmetics, or similar uses subject to specific regulatory requirements. Prior written approval from Covestro is required before this product may be used in any regulated application. The customer is solely responsible for ensuring compliance with all applicable laws and determining product suitability. Covestro disclaims all liability and warranties for unauthorized regulated uses.
Conditional Use for Medical Applications
This product may be suitable for certain medical application (e.g., medical devices). Use of this product in any medical application is subject to the requirements in Covestro’s guidance document ‘Guidance on Use of Covestro Products in a Medical Application’. As discussed in the document, limited applications require prior written approval from Covestro. Covestro disclaims all liability for medical uses not in compliance with this guidance.
Guidance on Use of Covestro Products in a Medical Application
Conditional Use in Regulated Applications
This product may be suitable for use in drinking water contact, food contact, toys. However, use in such applications requires prior written approval from Covestro. Legal requirements for such applications vary by country and jurisdiction, and the customer is solely responsible for verifying compliance with all applicable laws and regulations. Without Covestro’s written approval, the product may not be distributed or used for regulated purposes, and Covestro disclaims all liability for such use.
Typical Value
The values provided are typical only and do not represent binding specifications. Unless expressly confirmed in a written contract, these values are not part of the contractual quality agreement and must not be relied upon as a warranty or guarantee of product performance.
Sample
Samples provided by Covestro are intended solely for evaluation and testing purposes by the customer and may not be used in commercial applications, resold, transferred to third parties (except qualified testing service providers acting on behalf of the customer), reverse engineered, modified, or used in any manner not explicitly authorized in writing by Covestro. Samples are provided ‘as-is’ without any warranties, express or implied, including fitness for a particular purpose. Customers are solely responsible for ensuring safe handling, regulatory compliance, and suitability of the material for their intended evaluations. Covestro disclaims all liability for damages or losses arising from the use of samples.
Contact Information
Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .