Baymedix® AP501 is an aliphatic NCO-terminated prepolymer based on hexamethylene diisocyanate.
Product description
Specification
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
NCO content | 12,3 - 13,3 | % | DIN EN ISO 11909, Annex A | |
Viscosity | at 23 °C, Rotation | 4,000 ± 700 | mPa*s | DIN EN ISO 3219/A.3 |
HDI content | ≤ 0,099 | % | DIN EN ISO 10283 |
Typical Values
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Solids content | approx. 100 | % | ||
Density | at 20 °C | approx. 1,09 | g/cm3 | DIN 51757 |
Flash point | no flash point upto 250 | °C | DIN 51755 |
Storage
- Storage in original sealed Covestro container. - Recommended storage temperature: 10 - 30 °C. - Protect from moisture, heat and foreign material. General information : The product is highly sensitive to moisture and react with water to form carbon dioxide and insoluble ureas. The containers must always be kept tightly closed. Water in any form (moist air, water-containing solvents, wet containers) must be prevented from gaining access. A dangerous build-up of pressure can occur through the generation of carbon dioxide.
Storage time
Covestro represents that, for a period of six months following the day of shipment as stated in the respective transport documents, the product will meet the specifications or values set forth in section "specifications or characteristic data" above, what ever is applicable, provided that the product is stored in full compliance with the storage conditions set forth in and referenced under section "storage" above and is otherwise handled appropriately.The lapse of the six months period does not necessarily mean that the product no longer meets specifications or the set values. However, prior to using said product, Covestro recommends to test such a product if it still meets the specifications or the set values. Covestro does not make any representation regarding the product after the lapse of the six months period and Covestro shall not be responsible or liable in any way for the product failing to meet specifications or the set values after the lapse of the six months period.
Health and Safety Information
Before working with this product, you must read and become familiar with the available information on its risks, proper use, and handling. Information is available in several forms, e.g., in particular in the currently valid safety data sheets and product labels. For further information contact your Covestro representative.
Disclaimer
General
The manner in which you use our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is imperative that you test our products to determine suitability for your processing and intended uses. Your analysis must at least include testing to determine suitability from a technical, health, safety, and environmental and regulatory standpoint. Such testing has not necessarily been done by Covestro, and Covestro has not obtained any approvals or licenses for a particular use or application of the product.
Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which are available upon request.
All information and including technical assistance is given without warranty or guarantee and is subject to change without notice. It is expressly understood and agreed by you that you assume and hereby expressly release indemnify us and hold us harmless from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with any claim of any patent relative to any material or its use. No license is implied or in fact granted under the claims of any patent.
Medical Grades
All products for medical applications/Baymedix® products offered by Covestro are supplied under contract containing detailed product specifications and therefore the execution of an individual written supply contract is mandatory prior to any use of a medical applications/Baymedix® product, including but not limited to production of medical devices or medicinal products.
For more information, please refer to the Guidance on the use of Covestro products in Medical Applications:
Sample
Any samples provided by Covestro are for testing purposes only and not for commercial use.
Typical value
These values are typical values only. Unless explicitly agreed in written form, they do not constitute a binding material specification or warranted values
Contact
Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .