Imprafix® 2794

Waterbased aliphatic blocked polyisocyanate.Imprafix® 2794 is crosslinker with improved reactivity and thermostability (yellowing). It is being used for textile coatings based on Impranil and Impraperm Polyurethane Dispersions.

Contact an Expert
i
Market Switch
Selection will influence the results you get.
Copied to clipboard

About

Product Types

No data available

Material

No data available

General Characterization

No data available

Storage Conditions

No data available

Sampling

No data available

Packaging Type

No data available

Technical Properties & Datasheets

Product description

Waterbased aliphatic blocked polyisocyanate.Imprafix® 2794 is crosslinker with improved reactivity and thermostability (yellowing). It is being used for textile coatings based on Impranil and Impraperm Polyurethane Dispersions.

Form supplied

approx. 38 % in water

Specification

Property Test Condition Value Unit Standard
Non-volatile content (1g / 60min / 105°C) 38,0 ± 1 % DIN EN ISO 3251
Viscosity at 23 °C, D = 40 s^-1 < 100 mPa*s DIN EN ISO 3219/A.3
pH-value at 20 °C 6,5 - 8,5 DIN ISO 976

Typical Values

Property Test Condition Value Unit Standard
NCO content (blocked, calculated on solid resin) 11,5 ± 0,5 %

Solubility / thinnability

Imprafix® 2794 can be thinned with water. The compatibility and storage stability of the thinned solutions should always be tested, particularly if cosolvents are used.

Storage

- Storage in original sealed Covestro container. - Recommended storage temperature: 5 - 23 °C. - Protect from moisture, heat and foreign material.

Storage time

Covestro represents that, for a period of six months following the day of shipment as stated in the respective transport documents, the product will meet the specifications or values set forth in section "specifications or characteristic data" above, what ever is applicable, provided that the product is stored in full compliance with the storage conditions set forth in and referenced under section "storage" above and is otherwise handled appropriately. The lapse of the six months period does not necessarily mean that the product no longer meets specifications or the set values. However, prior to using said product, Covestro recommends to test such a product if it still meets the specifications or the set values. Covestro does not make any representation regarding the product after the lapse of the six months period and Covestro shall not be responsible or liable in any way for the product failing to meet specifications or the set values after the lapse of the six months period.

Health and Safety Information

Before working with this product, you must read and become familiar with the available information regarding its risks, proper use, and safe handling. This information is provided in various formats, including the current Safety Data Sheet (SDS) and product label. SDS can be accessed via the following link:

Safety Data Sheets (SDS) for Covestro products | Covestro

For further questions, please use the contact information provided on this technical data sheet.

Disclaimer

Responsibility and Liability

The use of Covestro products, technical assistance, and information (regardless of how provided) is outside Covestro’s control and is solely the responsibility of the customer. The customer must conduct adequate testing to determine the suitability of products for its intended use, including but not limited to technical, health, safety, and environmental aspects. Unless otherwise agreed in writing, all products are sold exclusively under Covestro’s standard conditions of sale, which prevail in case of conflict and are available upon request.
The terms and conditions of sale and delivery are available via the following link:

https://order.covestro.com/covestrostorefront/saleConditions

All information is provided “as is” without warranties, express or implied, including merchantability or fitness for a particular purpose, and is subject to change without notice. To the maximum extent permitted by law, Covestro disclaims, and the customer assumes all liability for losses, damages, or claims arising out of use of Covestro products, technical assistance, or information. Any statement or recommendation not expressly contained in Covestro documentation is unauthorized and shall not bind Covestro. Nothing herein shall be construed as encouraging or recommending the use of any product in conflict with any claim of any patent. No license is implied or in fact granted under the claims of any patent.

Restrictions on Regulated Applications

This product is not intended for use in regulated applications such as agriculture, cosmetics, drinking water contact, food contact, medical products (e.g., medical devices), toys, or similar uses subject to specific regulatory requirements. Prior written approval from Covestro is required before this product may be used in any regulated application. The customer is solely responsible for ensuring compliance with all applicable laws and determining product suitability. Covestro disclaims all liability and warranties for unauthorized regulated uses.

Typical Value

The values provided are typical only and do not represent binding specifications. Unless expressly confirmed in a written contract, these values are not part of the contractual quality agreement and must not be relied upon as a warranty or guarantee of product performance.

Sample

Samples provided by Covestro are intended solely for evaluation and testing purposes by the customer and may not be used in commercial applications, resold, transferred to third parties (except qualified testing service providers acting on behalf of the customer), reverse engineered, modified, or used in any manner not explicitly authorized in writing by Covestro. Samples are provided ‘as-is’ without any warranties, express or implied, including fitness for a particular purpose. Customers are solely responsible for ensuring safe handling, regulatory compliance, and suitability of the material for their intended evaluations. Covestro disclaims all liability for damages or losses arising from the use of samples.

Contact Information

Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .

Downloads

Technical Data Sheet
Download
Safety Data Sheet
No direct download available, please visit www.productsafetyfirst.covestro.com

Related topics

Do you want to know more about Imprafix® 2794?
Get in touch with our experts!

contact us

Over welk onderwerp neemt u contact met ons op?

Hoe zou u uzelf omschrijven?

In welk type materiaal bent u geïnteresseerd?

In welk type industrie bent u geïnteresseerd?

Wat voor aanvraag is dit?

Hoe kunnen wij contact met u opnemen?

Wat is het onderwerp van uw aanvraag?

Uw bericht aan ons

*Verplichte velden

Informatie over gegevensverwerking vindt u in ons privacybeleid.

Request a sample
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"nl","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"No results for","MaxItem":5}

Request a quote
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"nl","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"No results for","MaxItem":5}

Compare