- Plastics
Makrolon® TC629 RE CQ
high thermal conductivity; flame retardant; components for heat dissipation
i
Market Switch
Selection will influence the results you get.
About
Product Types
No data available
Material
- Plastics
- CQ renewable attributed
General Characterization
No data available
Storage Conditions
No data available
Sampling
No data available
Packaging Type
No data available
Technical Properties & Datasheets
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Barrel Temperatures - Front | - | °C | 300 - 320 | |
Barrel Temperatures - Middle | - | °C | 290 - 310 | |
Barrel Temperatures - Nozzle | - | °C | 310 - 330 | |
Barrel Temperatures - Rear | - | °C | 280 - 300 | |
Dry Air Drying Temperature | - | °C | 120 | |
Dry Air Drying Time | - | h | 4 | |
Hold Pressure (% of injection pressure) | - | % | 50 - 75 | |
Melt temperatures | - | °C | 320 | |
Moisture Content max. (%) | - | % | <0.2 | |
Mold Temperatures | - | °C | 80 - 90 | |
Peripheral Screw Speed | - | m/s | 0.05 - 0.2 | |
Plastic Back Pressure (specific) | - | bar | 50 - 150 | |
Shot-to-Cylinder Size | - | % | 30 - 70 | |
Vent Depth | - | mm | 0.0025 - 0.075 |
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Burning behavior UL 94 [UL recognition] | UL 94 | 2.0 mm | Class | V-0 (BK) |
Coefficient of linear thermal expansion, normal | ISO 11359-1,-2 | 23 to 55 °C | 10^-4^/K | 0.44 |
Coefficient of linear thermal expansion, parallel | ISO 11359-1,-2 | 23 to 55 °C | 10^-4^/K | 0.31 |
Glow wire test (GWFI) | IEC 60695-2-12 | 1.5 mm | °C | 960 |
Glow wire test (GWFI) | IEC 60695-2-12 | 3.0 mm | °C | 960 |
Glow wire test (GWIT) | IEC 60695-2-13 | 1.5 mm | °C | 900 |
Glow wire test (GWIT) | IEC 60695-2-13 | 3.0 mm | °C | 960 |
Temperature of deflection under load | ISO 75-1,-2 | 0.45 MPa | °C | 143 |
Temperature of deflection under load | ISO 75-1,-2 | 1.80 MPa | °C | 137 |
Thermal conductivity, in-plane | ASTM E1461 | 23 °C; 50 % r. h. | W/(m*K) | 15 |
Thermal conductivity, through-plane | ASTM E1461 | 23 °C; 50 % r. h. | W/(m*K) | 1.2 |
Vicat softening temperature | ISO 306 | 50 N; 50 °C/h | °C | 144 |
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Charpy impact strength | ISO 179/1eU | 23 °C | kJ/m² | 6 |
Charpy notched impact strength | ISO 179/1eA | 23 °C | kJ/m² | 2 |
Flexural modulus | ISO 178 | 2 mm/min | MPa | 7400 |
Flexural strain at flexural strength | ISO 178 | 2 mm/min | % | 1 |
Flexural strength | ISO 178 | 2 mm/min | MPa | 58 |
Strain at break | ISO 527-1,-2 | 5 mm/min | % | 1.0 |
Stress at break | ISO 527-1,-2 | 5 mm/min | MPa | 41 |
Tensile modulus | ISO 527-1,-2 | 1 mm/min | MPa | 6500 |
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Melt viscosity | b.o. ISO 11443-A | 1000 s^-1^/ 330 °C | Pa*s | 145 |
Melt viscosity | b.o. ISO 11443-A | 1000 s^-1^/ 300 °C | Pa*s | 270 |
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Surface resistivity | IEC 62631-3-2 | Ohm | 4.1E03 | |
Volume resistivity | IEC 62631-3-1 | Ohm*m | 2.1E04 |
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Injection molding - Melt temperature | ISO 294 | °C | 330 | |
Injection molding - Mold temperature | ISO 294 | °C | 85 |
Property Name | Standard | Test condition | Unit | Value |
---|---|---|---|---|
Density | ISO 1183-1 | kg/m³ | 1380 |
Downloads
-
Technical Data Sheet
-
Safety Data SheetNo direct download available, please visit www.productsafetyfirst.covestro.com