Applications
Injection molding; Films for medical packaging; Contact lens holders; Medical vessels; Safety valve for respiration aids; Syringe tops
Typical Values
Rheological properties
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Melt Volume-flow Rate (MVR) | 330 °C/ 2.16 kg | 17 | cm³/10 min | ISO 1133-1 |
Melt Mass-flow Rate (MFR) | 330 °C/ 2.16 kg | 17 | g/10 min | ISO 1133-1 |
Molding Shrinkage, parallel | 60x60x2 mm | 0.8 | % | ISO 294-4 |
Molding Shrinkage, parallel | 60x60x2 mm/ 500 bar | 0.85 | % | ISO 294-4 |
Molding Shrinkage, normal | 60x60x2 mm | 0.8 | % | ISO 294-4 |
Molding Shrinkage, normal | 60x60x2 mm/ 500 bar | 0.85 | % | ISO 294-4 |
Mechanical properties (23 °C/50 % r. h.)
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Tensile modulus | 1 mm/min | 2,400 | MPa | ISO 527-1,-2 |
Yield Stress | 50 mm/min | 70 | MPa | ISO 527-1,-2 |
Yield Strain | 50 mm/min | 6.8 | % | ISO 527-1,-2 |
Nominal Strain at Break | 50 mm/min | > 50 | % | ISO 527-1,-2 |
Flexural Modulus | 2 mm/min | 2,400 | MPa | ISO 178 |
Ball Indentation Hardness | 120 | N/mm² | ISO 2039-1 |
Thermal properties
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Temperature of Deflection under Load | 0.45 MPa | 161 | °C | ISO 75-1,-2 |
Temperature of Deflection under Load | 1.80 MPa | 148 | °C | ISO 75-1,-2 |
Vicat Softening Temperature | 50 N; 120 °C/h | 170 | °C | ISO 306 |
Coefficient of Linear Thermal Expansion, parallel | 23 to 55 °C | 0.65 | 10⁻⁴/K | ISO 11359-1,-2 |
Coefficient of Linear Thermal Expansion, normal | 23 to 55 °C | 0.65 | 10⁻⁴/K | ISO 11359-1,-2 |
Burning Behavior | 1.5 mm | HB | UL 94 | |
Oxygen Index | Method A | 25 | % | ISO 4589-2 |
Glow Wire Test (GWFI) | 850 | °C | IEC 60695-2-12 | |
Glow Wire Test (GWFI) | 2.0 mm | 850 | °C | IEC 60695-2-12 |
Electrical properties (23 °C/50 % r. h.)
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Relative Permittivity | 1 MHz | 2.9 | IEC 60250 | |
Relative Permittivity | 100 Hz | 3 | IEC 60250 | |
Dielectric Dissipation Factor | 1 MHz | 80 | 10⁻⁴ | IEC 60250 |
Dielectric Dissipation Factor | 100 Hz | 10 | 10⁻⁴ | IEC 60250 |
Volume Resistivity | 1E15 | Ω·m | IEC 60093 | |
Volume Resistivity | 1E15 | Ω·m | IEC 62631-3-1 | |
Surface Resistivity | 1E16 | Ω | IEC 60093 | |
Surface Resistivity | 1E16 | Ω | IEC 62631-3-2 | |
Electric Strength | 1 mm | 35 | kV/mm | IEC 60243-1 |
Comparative Tracking Index (CTI) | Solution A | 250 | IEC 60112 | |
Comparative Tracking Index (CTI M) | Solution B | 125 | IEC 60112 | |
Electrolytic Corrosion | A1 | IEC 60426 |
Other properties (23 °C)
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Water Absorption (Saturation Value) | Water at 23 °C | 0.3 | % | ISO 62 |
Water Absorption (Equilibrium Value) | 23 °C; 50 % r. h. | 0.12 | % | ISO 62 |
Density | 1,170 | kg/m³ | ISO 1183-1 |
Material specific properties
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Luminous Transmittance (Clear Transparent Materials) | 1 mm | 88 | % | ISO 13468-2 |
Refractive Index | Procedure A | 1.578 | ISO 489 |
Processing conditions for test specimens
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Injection Molding - Melt Temperature | 330 | °C | ISO 294 | |
Injection Molding - Mold Temperature | 100 | °C | ISO 294 | |
Injection Molding - Injection Velocity | 200 | mm/s | ISO 294 |
Recommended processing and drying conditions
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
Standard Melt Temperature | 330 | °C | ||
Barrel Temperatures | Nozzle | 320 - 330 | °C | |
Barrel Temperatures | Front | 310 - 320 | °C | |
Barrel Temperatures | Middle | 300 - 310 | °C | |
Barrel Temperatures | Rear | 290 - 300 | °C | |
Mold Temperatures | 110 - 130 | °C | ||
Hold Pressure (% of Injection Pressure) | 50 - 75 | % | ||
Plastic Back Pressure (specific) | 50 - 150 | bar | ||
Peripheral Screw Speed | 0.05 - 0.2 | m/s | ||
Shot-to-Cylinder Size | 30 - 70 | % | ||
Dry Air Drying Temperature | 130 | °C | ||
Dry Air Drying Time | 2 - 3 | h | ||
Moisture Content max. (%) | ≤ 0.02 | % | ||
Vent Depth | 0.025 - 0.075 | mm |