Before working with this product, you must read and become familiar with the available information regarding its risks, proper use, and safe handling. This information is provided in various formats, including the current Safety Data Sheet (SDS) and product label. SDS can be accessed via the following link:
Safety Data Sheets (SDS) for Covestro products | Covestro
For further questions, please use the contact information provided on this technical data sheet.
Product description
Mondur MA 2903 is an isocyanate-terminated (MDI) prepolymer based on allophanate modified 4,4’-diphenylmethane-diisocyanate (MDI).
Applications
Mondur MA 2903 can be used as a raw material in the formation of elastomers, microcellular shoe soles, integral skin and semi-flexible urethane foams. As with any product, use of Mondur MA 2903 in a given application must be tested (including but not limited to field testing) in advance by the user to determine suitability. Material has a high propensity to become turbid over time. Turbity shall not be a cause for material rejection by the customer.
Typical Values
| Property | Test Condition | Value | Unit | Standard |
|---|---|---|---|---|
| Appearance | Light yellow to yellow; clear to slightly turbid liquid | |||
| Specific gravity | at 25°C | 1,19 | ||
| Flash point | PMCC | > 93 | °C | |
| Viscosity | at 25°C | 400 | mPa•s |
Storage
Mondur MA 2903 prepolymer must be stored in tightly closed containers and protected from contamination with moisture and foreign materials, which can adversely affect processing. It will react slowly with water to form ureas and carbon dioxide gas, which may cause sealed containers to expand and rupture. Partially filled containers should be blanketed with dry nitrogen. Recommended storage temperatures should be maintained between 24° to 38°C (75° to 100°F). Within this range, a storage temperature of about 25°C (77°F) will maximize the storage life of this product. Mondur MA 2903 prepolymer must not be allowed to freeze. Exposure to temperatures less than 15°C (59°F), even for short periods of time, can result in the formation of solid material. During the winter months, appropriate precautions must be taken during shipment and storage. Prolonged storage of solid or partially solid Mondur MA 2903 prepolymer may result in the formation of MDI dimer in amounts which exceed its solubility in the product at normal storage temepratures. This can make the product unusable. If solids should form because of exposure to low temperatures, it may be possible to reliquify Mondur MA 2903 by heating. Use a well-ventilated oven for the minimum time necessary to render it clear. The temperature of the product should not exceed 60°C (140°F). Agitation or drum rollers are recommended to avoid excessive local heating, which will degrade the product.Significant amounts of MDI dimer may form during the heating process. As a result, the remelted diisocyanate may be cloudy, and the processing behavior and/or properties of the final product may be affected. Mondur allophanate modified diisocyanates may show a noticeable color increase during the shelf-life of the product. This is normal behavior for this material and this changes should not impact overall product performance. Following the recommended storage temperature, as stated on the technical data sheet, and minimizing the storage time will minimize the color increase.The shelf life is six months after receipt of material by customer, when stored in sealed original containers under conditions stated above.
Health and Safety Information
Disclaimer
Responsibility and Liability
The use of Covestro products, technical assistance, and information (regardless of how provided) is outside Covestro’s control and is solely the responsibility of the customer. The customer must conduct adequate testing to determine the suitability of products for its intended use, including but not limited to technical, health, safety, and environmental aspects. Unless otherwise agreed in writing, all products are sold exclusively under Covestro’s standard conditions of sale, which prevail in case of conflict and are available upon request.
The terms and conditions of sale and delivery are available via the following link:
https://order.covestro.com/covestrostorefront/saleConditions
All information is provided “as is” without warranties, express or implied, including merchantability or fitness for a particular purpose, and is subject to change without notice. To the maximum extent permitted by law, Covestro disclaims, and the customer assumes all liability for losses, damages, or claims arising out of use of Covestro products, technical assistance, or information. Any statement or recommendation not expressly contained in Covestro documentation is unauthorized and shall not bind Covestro. Nothing herein shall be construed as encouraging or recommending the use of any product in conflict with any claim of any patent. No license is implied or in fact granted under the claims of any patent.
Restrictions on Regulated Applications
This product is not intended for use in regulated applications such as agriculture, cosmetics, drinking water contact, food contact, medical products (e.g., medical devices), toys, or similar uses subject to specific regulatory requirements. Prior written approval from Covestro is required before this product may be used in any regulated application. The customer is solely responsible for ensuring compliance with all applicable laws and determining product suitability. Covestro disclaims all liability and warranties for unauthorized regulated uses.
Typical Value
The values provided are typical only and do not represent binding specifications. Unless expressly confirmed in a written contract, these values are not part of the contractual quality agreement and must not be relied upon as a warranty or guarantee of product performance.
Sample
Samples provided by Covestro are intended solely for evaluation and testing purposes by the customer and may not be used in commercial applications, resold, transferred to third parties (except qualified testing service providers acting on behalf of the customer), reverse engineered, modified, or used in any manner not explicitly authorized in writing by Covestro. Samples are provided ‘as-is’ without any warranties, express or implied, including fitness for a particular purpose. Customers are solely responsible for ensuring safe handling, regulatory compliance, and suitability of the material for their intended evaluations. Covestro disclaims all liability for damages or losses arising from the use of samples.
Contact Information
Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .