Mondur® MA 2300

Kontaktieren Sie einen Experten
i
Markt wechseln
Die Auswahl beeinflusst die Ihnen angezeigten Ergebnisse.
In die Zwischenablage kopiert

Über

Materialklassen

  • MMDI

Material

Keine Daten verfügbar

Allgemeine Charakterisierung

Keine Daten verfügbar

Lagerungsbedingungen

Keine Daten verfügbar

Probenahme

Keine Daten verfügbar

Verpackungsart

Keine Daten verfügbar

Technische Eigenschaften & Datenblätter

Product description

Mondur MA 2300 is an allophanate modified 4,4’-diphenylmethane diisocyanate (MDI).

Applications

Mondur® MA 2300 diisocyanate can be used as a raw material for the preparaion of urethane foams, coatings, sealants and adhesives. As with any product, use of Mondur® MA 2300 in a given application must be tested (including but not limited to field testing) in advance by the user to determine suitability.

Specification

Property Test Condition Value Unit Standard
NCO content 22.7 - 23.3 % M105 - ISO 11909

Typical Values

Property Test Condition Value Unit Standard
Color yellow
Flash point 430 °C Pensky-Martens Closed Cup (ASTM D-93)
Property Test Condition Value Unit Standard
Appearance   Light yellow to yellow liquid    
Specific gravity at 25°C 1.2    
Flash point PMCC 93 °C  
Equivalent weight avg. 180    
Viscosity at 25°C 500 mPa•s  
Functionality   2.0    

Storage

Mondur® MA 2300 diisocyanate must be stored in tightly closed containers and protected from contamination with moisture and foreign materials, which can adversely affect processing. It will react slowly with water to form ureas and carbon dioxide gas, which may cause sealed containers to expand and rupture. Partially filled containers should be blanketed with dry nitrogen. Storage temperatures should be maintained between 10° to 30°C (50° to 86°F). Within this range, a storage temperature above 20°C (68°F) will maximize the storage life of this product.

Mondur® MA 2300 diisocyanate must not be allowed to freeze. Exposure to temperatures less than 0°C (32°F), even for short periods of time, can result in the formation of solid material. During the winter months, appropriate precautions must be taken during shipment and storage. Prolonged storage of solid or partially solid Mondur® MA 2300 diisocyanate may result in the formation of MDI dimer in amounts which exceed its solubility in the product at normal storage temepratures. This can make the product unusable. If solids should form because of exposure to low temperatures, it may be possible to reliquify Mondur® MA 2300 by heating. Use a well-ventilated oven for the minimum time necessary to render it clear. The temperature of the product should not exceed 60°C (140°F). Agitation or drum rollers are recommended to avoid excessive local heating, which will degrade the product.

Significant amounts of MDI dimer may form during the heating process. As a result, the remelted diisocyanate may be cloudy, and the processing behavior and/or properties of the final product may be affected. Mondur allophanate modified diisocyanates may show a noticeable color increase during the shelf-life of the product. This is normal behavior for this material and this changes should not impact overall product performance. Following the recommended storage temperature, as stated on the PIB, and minimizing the storage time will minimize the color increase.

Storage time

Covestro certifies that the product meets its specifications until the expiry date stated on the Certificate of Analysis, provided it has been stored and handled in accordance with Covestro’s specified conditions. Unless otherwise indicated, the expiry date is 6 months after quality control release. After expiry, product performance is not assured; customers are responsible for retesting material before use. Covestro makes no representations and assumes no liability for the product after the expiry date.

Health and Safety Information

Before working with this product, you must read and become familiar with the available information regarding its risks, proper use, and safe handling. This information is provided in various formats, including the current Safety Data Sheet (SDS) and product label. SDS can be accessed via the following link:

Safety Data Sheets (SDS) for Covestro products | Covestro

For further questions, please use the contact information provided on this technical data sheet.

Disclaimer

Responsibility and Liability

The use of Covestro products, technical assistance, and information (regardless of how provided) is outside Covestro’s control and is solely the responsibility of the customer. The customer must conduct adequate testing to determine the suitability of products for its intended use, including but not limited to technical, health, safety, and environmental aspects. Unless otherwise agreed in writing, all products are sold exclusively under Covestro’s standard conditions of sale, which prevail in case of conflict and are available upon request.
The terms and conditions of sale and delivery are available via the following link:

https://order.covestro.com/covestrostorefront/saleConditions

All information is provided “as is” without warranties, express or implied, including merchantability or fitness for a particular purpose, and is subject to change without notice. To the maximum extent permitted by law, Covestro disclaims, and the customer assumes all liability for losses, damages, or claims arising out of use of Covestro products, technical assistance, or information. Any statement or recommendation not expressly contained in Covestro documentation is unauthorized and shall not bind Covestro. Nothing herein shall be construed as encouraging or recommending the use of any product in conflict with any claim of any patent. No license is implied or in fact granted under the claims of any patent.

Restrictions on Regulated Applications

This product is not intended for use in regulated applications such as agriculture, cosmetics, drinking water contact, medical products (e.g., medical devices), toys, or similar uses subject to specific regulatory requirements. Prior written approval from Covestro is required before this product may be used in any regulated application. The customer is solely responsible for ensuring compliance with all applicable laws and determining product suitability. Covestro disclaims all liability and warranties for unauthorized regulated uses.

Conditional Use in Regulated Applications

This product may be suitable for use in food contact. However, use in such applications requires prior written approval from Covestro. Legal requirements for such applications vary by country and jurisdiction, and the customer is solely responsible for verifying compliance with all applicable laws and regulations. Without Covestro’s written approval, the product may not be distributed or used for regulated purposes, and Covestro disclaims all liability for such use.

Typical Value

The values provided are typical only and do not represent binding specifications. Unless expressly confirmed in a written contract, these values are not part of the contractual quality agreement and must not be relied upon as a warranty or guarantee of product performance.

Sample

Samples provided by Covestro are intended solely for evaluation and testing purposes by the customer and may not be used in commercial applications, resold, transferred to third parties (except qualified testing service providers acting on behalf of the customer), reverse engineered, modified, or used in any manner not explicitly authorized in writing by Covestro. Samples are provided ‘as-is’ without any warranties, express or implied, including fitness for a particular purpose. Customers are solely responsible for ensuring safe handling, regulatory compliance, and suitability of the material for their intended evaluations. Covestro disclaims all liability for damages or losses arising from the use of samples.

Contact Information

Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .

Downloads

Technisches Datenblatt
Sicherheitsdatenblatt
Kein direkter Download verfügbar, bitte besuchen Sie www.productsafetyfirst.covestro.com

Ähnliche Themen

Möchten Sie mehr über Mondur® MA 2300 erfahren?
Setzen Sie sich mit unseren Experten in Verbindung!

contact us

Zu welchem Thema möchten Sie uns heute kontaktieren?

Wie würden Sie sich selbst beschreiben?

Für welche Art von Material interessieren Sie sich?

An welcher Branche sind Sie interessiert?

Um welche Art von Anfrage handelt es sich?

Wie können wir Sie kontaktieren?

Was ist der Betreff Ihrer Anfrage?

Ihre Nachricht an uns

*Pflichtfelder

Informationen zur Datenverarbeitung finden Sie in unserer Datenschutzerklärung.

Muster anfordern
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"de","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"Keine Ergebnisse für","MaxItem":5}

Muster anfordern

Angebot anfragen
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&extended=true","Language":"de","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"Keine Ergebnisse für","MaxItem":5}

Compare