i
市场转换
选择会影响你得到的结果。
复制到剪贴板

关于

材料类型

无可用数据

材料

无可用数据

一般特征

无可用数据

储存条件

无可用数据

样品

无可用数据

包装类型

无可用数据

技术属性和数据表

Product description

Desmoderm® Additive Z is an aliphatic polyisocyanate based on hexamethylene diisocyanate (HDI). As the hardener component for lightfast polyurethane solutions.

Applications

The amount of Additive Z is generally from 2 – 10 %. When used in combination with suitable solvents and pigments (e.g. Bayderm® B and/or C Colors), Desmoderm® Additive Z has a pot life of 2 - 3 days. The use of Bayderm® A flüssig dyestuffs reduces the pot life to 2 – 4 hours. Suitable solvents are diacetone alcohol, cyclohexanone, tertiary butanol, dimethyl formamide, possibly combined with toluene, xylene or mixtures thereof.Common alcohols reduce the pot life to 3 – 4 hours. When applied in multiple layers (e.g. for demanding finishes applied via the transfer coating process), Desmoderm® Additive Z should only be added to the topmost layer of the finish (i.e. the first coat applied to the separation layer).

Form supplied

Approx. 75 % in 1-methoxypropylacetate-2/xylene, 1 : 1

Specification

Property Test Condition Value Unit Standard
NCO content 16,5 ± 0,3 % DIN EN ISO 11 909
Viscosity at 23 °C* 250 ± 75 mPa*s DIN EN ISO 3219/A.3
Non-volatile content (2.2 g/120 min./100 °C) 75 ± 1 % DIN EN ISO 3251
Hazen color value ≤ 40 DIN EN 1557
Monomeric HDI < 0,5 DIN EN ISO 10283

Typical Values

Property Test Condition Value Unit Standard
Equivalent weight approx. 225
Flash point approx. 38 °C DIN 53 213/1
Density at 20 °C approx. 1,07 g/cm3 DIN EN ISO 2811

Solubility / thinnability

Compatibility with the following solvents is generally good but the storage stability of the respective solutions should be tested.Desmoderm® Additive Z is reducible with ester and aromatic hydrocarbons such as ethyl acetate, butyl acetate, 1-methoxypropyl acetate-2, toluene and xylene. Aliphatic hydrocarbons are unsuitable.Desmoderm® Additive Z should not be thinned to less than 35 – 40 % non-volatile content. Prolonged storage of a solution with lower binder content may result in turbidity and sedimentation. Only PU grade solvents should be used (< 0.05 % water, free of reactive groups like hydroxyl or amino groups).

Storage

- Storage in original sealed Covestro container. - Recommended storage temperature: 5 - 25 °C. - Protect from moisture, heat and foreign material. General information: The product is sensitive to moisture. Storage at higher temperatures will result in increase of color and viscosity. Storage at significant lower temperatures will result in solidification. This solidification is reversible by briefly heating the product without adversely affecting the quality of the product.

Storage time

Covestro represents that, for a period of nine months following the day of shipment as stated in the respective transport documents, the product will meet the specifications or values set forth in section "specifications or characteristic data" above, what ever is applicable, provided that the product is stored in full compliance with the storage conditions set forth in and referenced under section "storage" above and is otherwise handled appropriately.The lapse of the nine months period does not necessarily mean that the product no longer meets specifications or the set values. However, prior to using said product, Covestro recommends to test such a product if it still meets the specifications or the set values. Covestro does not make any representation regarding the product after the lapse of the six months period and Covestro shall not be responsible or liable in any way for the product failing to meet specifications or the set values after the lapse of the six months period.

Health and Safety Information

Before working with this product, you must read and become familiar with the available information on its risks, proper use, and handling. Information is available in several forms, e.g.,  in particular in the currently valid safety data sheets and product labels. For further information contact your Covestro representative.

The Product Safety First Program | Covestro

Disclaimer

General

The manner in which you use our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is imperative that you test our products to determine suitability for your processing and intended uses. Your analysis must at least include testing to determine suitability from a technical, health, safety, and environmental and regulatory standpoint. Such testing has not necessarily been done by Covestro, and Covestro has not obtained any approvals or licenses for a particular use or application of the product.

Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which are available upon request.

All information and including technical assistance is given without warranty or guarantee and is subject to change without notice. It is expressly understood and agreed by you that you assume and hereby expressly release indemnify us and hold us harmless from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with any claim of any patent relative to any material or its use. No license is implied or in fact granted under the claims of any patent.

Non Medical and non Food Contact

This product is not designated for the manufacture of a medical device or of intermediate products for medical devices (1). This product is also not designated for other specifically regulated applications (e.g. including cosmetics, plant protection, fertilisers, plant strengtheners, food processing, food contact and others). If the intended use of the product is for the manufacture of a medical device or of intermediate products for medical devices or for other specifically regulated applications Covestro must be contacted in advance to provide its agreement to sell such product for such purpose. Nonetheless, any determination as to whether a product is appropriate for use in a medical device or intermediate products for medical devices, for Food Contact products or cosmetic applications must be made solely by the purchaser of the product without relying upon any representations by Covestro.

1) Please see the Guidance on Use of Covestro Products in a Medical Application document.

Sample

Any samples provided by Covestro are for testing purposes only and not for commercial use.

Typical value

These values are typical values only. Unless explicitly agreed in written form, they do not constitute a binding material specification or warranted values

Contact

Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .

下载

技术数据表
安全数据表
无可用直接下载,请访问 www.productsafetyfirst.covestro.com

你想知道更多关于 Z?
与我们的专家取得联系!

contact us

您如何形容自己?

您对什么类型的材料感兴趣?

你对哪种行业感兴趣?

这是什么类型的查询?

我们如何联系您?

* 必填字段

申请样品
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&CLIENTID=DHLTHP&CLIENTSECRET=2DNknMSM9HF5ubP2qdBg&extended=true","Language":"zh","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"没有结果","MaxItem":5}

请求一个样本

申请报价
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&CLIENTID=DHLTHP&CLIENTSECRET=2DNknMSM9HF5ubP2qdBg&extended=true","Language":"zh","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"没有结果","MaxItem":5}

Compare