Submit
  • Lacke, Farben & Druckfarben

Crelan® EF 403

Kontaktieren Sie einen Experten
i
Markt wechseln
Die Auswahl beeinflusst die Ihnen angezeigten Ergebnisse.
In die Zwischenablage kopiert

Über

Materialklassen

  • Vernetzer
  • Härter

Material

Lacke, Farben & Druckfarben
lösemittelfrei, Witterungsbeständig

Allgemeine Charakterisierung

Keine Daten verfügbar

Lagerungsbedingungen

Keine Daten verfügbar

Probenahme

Keine Daten verfügbar

Verpackungsart

Keine Daten verfügbar

Technische Eigenschaften & Datenblätter

Product description

Cycloaliphatic Polyuretdione without blocking agent. Hardener for polyurethane powder coatings

Applications

Technical grade
Cycloaliphatic polyuretdione (without blocking agent)
Hardener for hydroxyl functional polyesters and acrylic resins
Polyurethane powder coatings
Suitable for architectural and industrial purposes

Form supplied

Flakes

Specification

Property Test Condition Value Unit Standard
NCO content ≤ 2 % M105 - ISO 11909
Color Hazen ≤ 100 M017 - EN 1557
Glass transition temperature ≥ 40.0 °C M113 - ISO 11357

Typical Values

Principal properties

- Architectural and industrial
- Flow
- Flexibility
- Suitable for matt coatings
- Suitable for heat transfer coatings

 

Storage

- Storage in original sealed Covestro container. Additionally, we recommend to avoid piling up the pallets. - Recommended storage temperature: - 5 to 30 °C. - Protect from moisture, heat and foreign material. General information: The product is sensitive to moisture. Storage at higher temperatures will result in agglomeration of the product. This agglomeration is reversible by mechanical stress without adversely affecting the quality of the product.

Storage time

Covestro represents that, for a period of twelve months following the day of shipment as stated in the respective transport documents, the product will meet the specifications or values set forth in section "specifications or characteristic data" above, what ever is applicable, provided that the product is stored in full compliance with the storage conditions set forth in and referenced under section "storage" above and is otherwise handled appropriately. The lapse of the twelve months period does not necessarily mean that the product no longer meets specifications or the set values. However, prior to using said product, Covestro recommends to test such a product if it still meets the specifications or the set values. Covestro does not make any representation regarding the product after the lapse of the twelve months period and Covestro shall not be responsible or liable in any way for the product failing to meet specifications or the set values after the lapse of the twelve months period.

Processing

Crelan® EF 403 is primarily used to cure hydroxyl functional polyesters and acrylic resins
An OH : NCO  stoichiometric ratio (1:1) is recommended to produce optimum coating properties.

Starting formulation
Glossy, white powder coating

Component Weight
Crelan® EF 403 127.0
Uralac® P 5504 528.0
Titaniumdioxide* 330.0
Flow agent 10.0
Benzoin 5.0
Total 1000.0

* Raw material suppliers are available on request.

Extrusion process parameters
TSA FSCM 15-25 twin screw extruder
Setting temperatures: 60ºC/120ºC/115ºC
Speed: 400 rpm

Application process conditions
Coating thickness ≈60 µm
Cure Cycle 15' 200°C
Stoving in an air-circulated oven
Corona spray gun

Coating properties

Property Value Method
Reverse impact, AQT-46 7 Nm ASTM D2794
Reverse impact, S-46 18 Nm ASTM D2794
Storage stability (28 days 40°C) 9 DIN 55990-7

Health and Safety Information

Before working with this product, you must read and become familiar with the available information on its risks, proper use, and handling. Information is available in several forms, e.g.,  in particular in the currently valid safety data sheets and product labels. For further information contact your Covestro representative.

The Product Safety First Program | Covestro

Disclaimer

General

The manner in which you use our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is imperative that you test our products to determine suitability for your processing and intended uses. Your analysis must at least include testing to determine suitability from a technical, health, safety, and environmental and regulatory standpoint. Such testing has not necessarily been done by Covestro, and Covestro has not obtained any approvals or licenses for a particular use or application of the product.

Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which are available upon request.

All information and including technical assistance is given without warranty or guarantee and is subject to change without notice. It is expressly understood and agreed by you that you assume and hereby expressly release indemnify us and hold us harmless from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with any claim of any patent relative to any material or its use. No license is implied or in fact granted under the claims of any patent.

Non Medical and non Food Contact
This product is not designated for the manufacture of a medical device or of intermediate products for medical devices (1). This product is also not designated for other specifically regulated applications (e.g. including cosmetics, plant protection, fertilisers, plant strengtheners, food processing, food contact and others). If the intended use of the product is for the manufacture of a medical device or of intermediate products for medical devices or for other specifically regulated applications Covestro must be contacted in advance to provide its agreement to sell such product for such purpose. Nonetheless, any determination as to whether a product is appropriate for use in a medical device or intermediate products for medical devices, for Food Contact products or cosmetic applications must be made solely by the purchaser of the product without relying upon any representations by Covestro.

1) Please see the Guidance on Use of Covestro Products in a Medical Application document.

Sample

Any samples provided by Covestro are for testing purposes only and not for commercial use.

Typical value

These values are typical values only. Unless explicitly agreed in written form, they do not constitute a binding material specification or warranted values

Contact

Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .

Downloads

Technisches Datenblatt
Sicherheitsdatenblatt
Kein direkter Download verfügbar, bitte besuchen Sie www.productsafetyfirst.covestro.com

Möchten Sie mehr über Crelan® EF 403 erfahren?
Setzen Sie sich mit unseren Experten in Verbindung!

contact us

Zu welchem Thema möchten Sie uns heute kontaktieren?

Wie würden Sie sich selbst beschreiben?

Für welche Art von Material interessieren Sie sich?

An welcher Branche sind Sie interessiert?

Um welche Art von Anfrage handelt es sich?

Wie können wir Sie kontaktieren?

Was ist der Betreff Ihrer Anfrage?

Ihre Nachricht an uns

*Pflichtfelder

Informationen zur Datenverarbeitung finden Sie in unserer Datenschutzerklärung.

Muster anfordern
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&CLIENTID=DHLTHP&CLIENTSECRET=2DNknMSM9HF5ubP2qdBg&extended=true","Language":"de","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"Keine Ergebnisse für","MaxItem":5}

Muster anfordern

Angebot anfragen
{"FieldName":"ProductName","Endpoint":"https://covestro-prod-ffm.apimanagement.eu2.hana.ondemand.com/hybrispim/products_typeahead?identKey=GB6LiyNSG0YYxXXEpmO8EyoUdFLN0Roi&CLIENTID=DHLTHP&CLIENTSECRET=2DNknMSM9HF5ubP2qdBg&extended=true","Language":"de","PermissionQuery":"","BrandLabel":"Brand","ProductLabel":"Product","NoResultLabel":"Keine Ergebnisse für","MaxItem":5}

Compare