* Raw material suppliers are available on request.
Product description
Crelan NI 2 is a blocked aliphatic polyisocyanate based on IPDI. It is suitable as a hardener for polyurethane powder coatings.
Applications
Technical grade
Cycloaliphatic polyisocyanate blocked with caprolactam
Hardener for hydroxyl functional polyesters and acrylic resins
Polyurethane powder coatings
Suitable for architectural and industrial purposes
Form supplied
Flakes
Specification
Property | Test Condition | Value | Unit | Standard |
---|---|---|---|---|
NCO content | ≤ 1 | % | M105 - ISO 11909 | |
Dynamic viscosity | 160 °C | 1500 - 4500 | mPa·s | M058 - ISO 3219 |
Color | Hazen | ≤ 99 | M017 - EN 1557 | |
Glass transition temperature | ≥ 50.0 | °C | M113 - ISO 11357 |
Typical Values
Principal properties
- Architectural and industrial
- Flow
- High NCO content
- High coating Tg
- Clarity, also suitable for clear coatings
- Excellent gloss retention and chalking resistance in outdoor weathering
- Corrosion resistance
- Storage stability
Storage
Crelan NI 2 should be stored in tightly sealed original containers and protected from moisture, heat, and foreign materials. The product is sensitive to moisture. Storage at higher temperatures will result in agglomeration of the product. This agglomeration is reversible by mechanical stress without adversely affecting the quality of the product. Recommended storage temperature is -5 to 40°C.
Storage time
Crelan NI 2 has a shelf life of twelve months from date of receipt at customer, provided the material is stored in sealed original containers at the recommended storage temperature.
Processing
Crelan® NI-2 is primarily used to cure hydroxyl functional polyesters and acrylic resins
An OH : NCO stoichiometric ratio (1:1) is recommended to produce optimum coating properties.Slight undercrosslinking (OH/NCO ratio 1:1.1) is possible depending on the co-reactants used and the film properties required. Overcrosslinking produces no advantages.
Starting formulation
Glossy, white powder coating
Component | Weight |
---|---|
Crelan® NI 2 | 127.0 |
Uralac® P 5504 |
528.0 |
Titaniumdioxide* | 330.0 |
Flow agent | 10.0 |
Benzoin | 5.0 |
Total | 1000.0 |
Extrusion process parameters
TSA FSCM 15-25 twin screw extruder
Setting temperatures: 60ºC/120ºC/115ºC
Speed: 400 rpm
Application process conditions
Coating thickness ≈60 µm
Cure Cycle 12' 200°C
Stoving in an air-circulated oven
Corona spray gun
Coating properties
Property | Value | Method |
---|---|---|
Reverse impact, AQT-46 | 7 Nm | ASTM D2794 |
Reverse impact, S-46 | 18 Nm | ASTM D2794 |
Storage stability (28 days 40°C) | 9 | DIN 55990-7 |
Health and Safety Information
Before working with this product, you must read and become familiar with the available information on its risks, proper use, and handling. Information is available in several forms, e.g., in particular in the currently valid safety data sheets and product labels. For further information contact your Covestro representative.
Disclaimer
General
The manner in which you use our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is imperative that you test our products to determine suitability for your processing and intended uses. Your analysis must at least include testing to determine suitability from a technical, health, safety, and environmental and regulatory standpoint. Such testing has not necessarily been done by Covestro, and Covestro has not obtained any approvals or licenses for a particular use or application of the product.
Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which are available upon request.
All information and including technical assistance is given without warranty or guarantee and is subject to change without notice. It is expressly understood and agreed by you that you assume and hereby expressly release indemnify us and hold us harmless from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with any claim of any patent relative to any material or its use. No license is implied or in fact granted under the claims of any patent.
Non Medical and non Food Contact
This product is not designated for the manufacture of a medical device or of intermediate products for medical devices (1). This product is also not designated for other specifically regulated applications (e.g. including cosmetics, plant protection, fertilisers, plant strengtheners, food processing, food contact and others). If the intended use of the product is for the manufacture of a medical device or of intermediate products for medical devices or for other specifically regulated applications Covestro must be contacted in advance to provide its agreement to sell such product for such purpose. Nonetheless, any determination as to whether a product is appropriate for use in a medical device or intermediate products for medical devices, for Food Contact products or cosmetic applications must be made solely by the purchaser of the product without relying upon any representations by Covestro.
1) Please see the Guidance on Use of Covestro Products in a Medical Application document.
Sample
Any samples provided by Covestro are for testing purposes only and not for commercial use.
Typical value
These values are typical values only. Unless explicitly agreed in written form, they do not constitute a binding material specification or warranted values
Contact
Please use our contact form or contact us directly by sending an e-mail to technical-datasheets@cx.covestro.com .